Our racks, your workloads โ or ours.
CloudTechtiq runs the facility layer as well as the cloud on top of it. Colocate your own hardware, take managed HPE infrastructure, or consume it as cloud capacity โ from the same UAE floor, on one contract, billed in AED.
- Carrier-neutral
- 2N power ยท N+1 cooling
- 24ร7 remote hands
- ISO 27001:2022
Built like infrastructure, not like a server room.
Contained cold aisles, redundant power paths to every cabinet, and metered circuits so the invoice reflects what you actually drew. The same halls run our public cloud โ which means when you buy cloud from us, you are buying from the operator, not from a reseller of somebody elseโs floor space.
Power to rack
Up to 12 kW
higher density by arrangement
Power topology
2N UPS
A+B feeds to every rack
Generators
N+1 diesel
48-hour on-site fuel
Cooling
N+1 CRAC
hot/cold aisle containment
Carriers
Carrier-neutral
multiple UAE providers on net
Access control
Multi-factor
mantrap, biometric, 90-day CCTV
Facility specifications are indicative and confirmed per site during the design review.
Three ways to take the same infrastructure.
Most UAE enterprises need more than one. The point of running the facility ourselves is that you can mix all three without moving vendors, and move workloads between them without an egress bill.
Colocation
Your hardware, our power, cooling, network and hands. You keep the asset on your balance sheet.
Managed dedicated
HPE ProLiant or Alletra we supply, install and operate. Single-tenant hardware, no capex.
Cloud platform
Compute, storage, Kubernetes and GPU consumed by the hour from the same halls.
What the hall actually looks like
A facility tour can be arranged before you sign anything. These are representative of what you'd see on the visit.
What you get on the floor
Colocation is judged on the boring things โ whether the power holds, whether the cooling copes in August, and whether someone answers at 3am. These are ours.
Power that does not blink
Dual A+B feeds from independent UPS strings, N+1 generator backup and on-site fuel. Every circuit is metered so you are billed on measured draw, not a nominal allocation.
Cooling sized for real density
Hot and cold aisle containment with N+1 precision cooling. Standard racks are provisioned to 6 kW with higher density available in dedicated high-power rows.
Carrier-neutral connectivity
Cross-connect to the UAE carriers and transit providers you already use. No forced transit, no markup on a single incumbent, and diverse entry paths into the building.
Physical security in layers
Perimeter, lobby, hall and cabinet โ four separate controls. Biometric plus card at the hall, mantrap entry, and CCTV retained to the period stated in our privacy policy.
Audited, not asserted
Operated to ISO 27001:2022 and covered by our SOC 2 Type II report. Evidence packs, floor plans and access logs are available to customers under NDA.
Remote hands, around the clock
Reboots, media swaps, cabling and cross-connects handled by on-site engineers 24ร7ร365. Included allowance on every contract, then billed by the quarter hour.
Presence across the Emirates.
Primary capacity in Dubai, secondary site for Abu Dhabi replication, and edge presence for latency-sensitive workloads. Data stays in country unless you explicitly configure otherwise.
Diagram is illustrative of service coverage and is not a survey-accurate map.
Independently verified, not self-declared
Uptime Institute Tier III
Concurrently maintainable, N+1 across critical systems
ISO 27001
Information security management
PCI DSS Level 1
Payment card hosting environment
UAE Data Protection Law
In-country data residency compliant
Colocation pricing
Monthly, in AED, excluding 5% UAE VAT. Power billed on metered draw. Twelve-month terms; longer commitments reduce the rate.
| Configuration | Power | Feeds | From / month |
|---|---|---|---|
| Quarter rack โ 10U | 2 kW | A+B metered | AED 1,450 |
| Half rack โ 21U | 4 kW | A+B metered | AED 2,600 |
| Full rack โ 42U | 6 kW | A+B metered | AED 4,400 |
| Full rack โ high density | 12 kW | A+B metered | AED 7,900 |
| Private cage โ from 6 racks | On design | Dedicated PDU | On application |
| Cross-connect โ single mode fibre | โ | โ | AED 350 |
Prices exclude 5% UAE VAT and cross-connect fees where applicable. Installation and remote hands allowances are set per contract.
Frequently asked questions
We operate from carrier-neutral data centre space in the Dubai metro, with a secondary site serving Abu Dhabi for replication and disaster recovery. Exact addresses are released to customers under NDA as part of the security review โ a standard practice in colocation, since publishing a rack location is itself a security weakness.
Yes. Colocation customers rack their own equipment, and we will receive, inventory and install it. If you would rather not buy hardware at all, our cloud platform runs on the same floor, and we also supply HPE compute and storage if you want owned kit without procuring it yourself.
On metered draw, per rack, in AED. You are not charged for a nominal allocation you never use. Each rack reports A and B feed consumption and the figures appear on your monthly invoice.
That is the most common design we deploy. Licensed or latency-sensitive workloads sit on your own hardware in the cage, burst and non-production capacity runs on our cloud platform, and the two connect over a private VLAN inside the facility with no internet path and no egress charge between them.
Scheduled escorted access 24ร7 for named individuals on your authorised list. Additions to that list require written authorisation from your nominated contact. Emergency access is available at any hour with phone verification.
Remote hands. Our engineers are on the floor 24ร7ร365 and will perform reboots, swaps, re-cabling and diagnostics on your instruction. Every contract includes a monthly allowance before hourly charges begin.